Search results for "Voltage source"

showing 10 items of 28 documents

The Effect of the Harmonic Content Generated by AC/DC Modular Multilevel Converters on HVDC Cable Systems

2019

With the increasing penetration of renewable and decentralized energy sources into the power grid, an extended use of DC voltages is expected on both distribution and transmission levels. Generation of DC voltages by means of voltage source converters is associated with a wide spectrum of harmonic distortions at converter terminals, both on the ac and on the dc sides. This can lead to partial discharges in power cables, which deteriorate insulation material thus weakening its performance and reducing cable life-time. In the previously published paper, the effect of harmonic distortion on appearance of partial discharges in cable insulation was evaluated. Here, the study related to the PD be…

010302 applied physicsTotal harmonic distortionbusiness.industryComputer scienceripple020209 energyElectrical engineering02 engineering and technologyDC streConvertersmultilevel converter01 natural sciencesHarmonic analysisSynchronization (alternating current)partial dischargeSettore ING-IND/31 - ElettrotecnicaharmonicHarmonics0103 physical sciences0202 electrical engineering electronic engineering information engineeringHarmonicPDWaveformVoltage sourcebusiness2019 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)
researchProduct

Current fault signatures of Voltage Source Inverters in different reference frames

2016

This paper considers different current patterns used to identify the correct fault signatures in Voltage Source Inverters (VSI). At the beginning, the Authors consider the currents patterns from which a simple or a double fault can be encompassed both in the case of controllable device only or with its free wheeling companion diode. After the discussion of diagnosis algorithm suitable for electrical drives and principally based on a persistent near zero current condition current in the natural phase reference frame, the stationary reference frame is then considered as a tool to identify both the faulted phase as the device or various combination of faulted devices. On the contrary, the Auth…

0209 industrial biotechnologyEngineeringControl and Optimization02 engineering and technologyFault (power engineering)020901 industrial engineering & automationControl theory0202 electrical engineering electronic engineering information engineeringElectronic engineeringVoltage sourceDouble faultPWM inverterElectrical and Electronic EngineeringStationary Reference Framebusiness.industryMechanical Engineering020208 electrical & electronic engineeringControl reconfigurationFault toleranceRotating reference frameVoltage Source InverterFaultAutomotive EngineeringbusinessReference frameDiagnosi
researchProduct

Algebraic real-time algorithm for B-Spline sinusoidal pulse width modulation in three phase voltage source inverters.

2008

In this paper a novel algebraic real-time algorithm for implementation of sinusoidal pulse width modulation (SPWM) based on B-spline carriers is introduced and discussed. B-spline functions are used as carrier signals with the aim to to reduce harmonic content of the three phase inverter output voltage. This algorithm eliminates the problem of B-spline recursive evaluation with convolution integrals or convolution sums in digital counterpart. The pulse pattern synthesis is made with the help pre-calculated duty cycle expressions. In this way the carrier signals have not to be really synthesized, hence the hardware and the whole inverter control system becomes cheaper, more reliable and affo…

Amplitude modulationTotal harmonic distortionThree-phaseControl theoryDuty cycleInverterVoltage sourcePower factorPulse-width modulationMathematics2008 IEEE International Symposium on Industrial Electronics
researchProduct

An Adaptive Robust Predictive Current Control for Three-Phase Grid-Connected Inverters

2011

This paper presents an adaptive robust predictive current control (RPCC) for grid-connected three-phase inverters that exhibit zero steady-state current error. The error correction is achieved by means of an adaptive strategy that works in parallel with the deadbeat algorithm, therefore preserving the typical fast response of the predictive law. The resulting control adapts to any particular L or LCL filter by estimation of the resistive part of the filter. As a variety of the RPCC class of control, it offers the best tradeoff between robustness and speed. © 2009 IEEE.

EngineeringAdaptive controlThree-phase inverterGrid connected invertersElectric current controlElectric invertersTECNOLOGIA ELECTRONICAControl theoryRobustness (computer science)Active power filteringCurrent-controlled voltage source invertersFast responseElectrical and Electronic EngineeringActive filterAdaptive strategyActive filtersActive power filtering (APF)Power convertersbusiness.industryGrid-connectedPredictive current controlGridSteady-state currentsDeadbeat algorithmModel predictive controlCurrent-controlled voltage source inverter (VSI)Robust predictive current control (RPCC)Three-phaseControl and Systems EngineeringRobust controlLCL filtersError detection and correctionbusinessIEEE Transactions on Industrial Electronics
researchProduct

Experimental validation of a general model for three phase inverters operating in healthy and faulty modes

2012

The paper presents the experimental verification of a general mathematical model of Voltage Source Inverters (VSI) able to simulate fault conditions and which is also useful for the simulation of fault-tolerant systems for different applications. In general, in the past, the problem of faulty inverters modeling has been addressed specifically by considering faults on the different phases as separate cases. Furthermore, traditional models include only the faulty mode and not the healthy mode, so resulting then not able to predict transient phenomena. The model hereafter presented overcomes this drawback. It was formulated by introducing the concept of “healthy leg binary variables”. Such var…

EngineeringCorrectnessCircuit faults Fault tolerance Fault tolerant systems Integrated circuit modeling Inverters Mathematical model Vectorsbusiness.industryFault toleranceControl engineeringHardware_PERFORMANCEANDRELIABILITYSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault (power engineering)Fault indicatorStuck-at faultComputer Science::Hardware ArchitectureThree-phaseTransient (oscillation)Voltage sourcebusinessComputer Science::Operating SystemsComputer Science::Distributed Parallel and Cluster ComputingInternational Symposium on Power Electronics Power Electronics, Electrical Drives, Automation and Motion
researchProduct

Decoupled control scheme of the grid-connected split-source inverter for renewable energy sources

2016

Grid-connected power conversion systems for renewable energy sources must fulfill several requirements, including high efficiency, reduced cost and complexity, and, quite often, also boost capabilities from the dc sources to the ac power grid. For such applications, single-stage power converters with boost capabilities offer some potential advantages. Among several proposed options, split-source inverter (SSI) has been recently investigated. This paper proposes a decoupled control scheme for the SSIs, where the common mode term of the ac modulation signals is used to control the dc input current. Thus, the dc input current and ac output current can be controlled independently. The proposed …

EngineeringGrid connection; Renewable energy sources; Single-stage; Split-source inverter; Voltage source inverter; Z-source inverter; Control and Systems Engineering; Electrical and Electronic EngineeringRenewable energy source02 engineering and technologySettore ING-INF/01 - ElettronicaRenewable energy sourcesSplit-source inverter0202 electrical engineering electronic engineering information engineeringGrid connectionSingle-stageElectrical and Electronic EngineeringVoltage source inverterbusiness.industryGrid connection020208 electrical & electronic engineeringElectrical engineering020206 networking & telecommunicationsZ-source inverterAC powerConvertersGridRenewable energyPower (physics)Control and Systems EngineeringInverterbusinessZ-source inverter
researchProduct

Mathematical modelling of an inverter-based distributed generator

2016

In this paper, a modeling approach of a three phase power inverter based on an electrostatic synchronous machine is presented. By the proposed approach, any inverter-based distributed generator in a microgrid can be replaced by an equivalent electrostatic machine. This paper aims to promote the use of the proposed modeling approach in the analysis of microgrid stability. Thanks to the proposed modeling approach, transient performances of on-grid operation of converter-based distributed generators could be easily analyzed by multi-machine models. Parameters of the equivalent synchronous electrostatic machine model are derived to achieve equivalence with the inverter model. Small signal model…

EngineeringMicrogridbusiness.industry020209 energy02 engineering and technologyDistributed GeneratorVoltage Source InverterStability of microgridSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaElectrostatic Synchronous MachineThree-phaseControl theoryElectrostatic generator0202 electrical engineering electronic engineering information engineeringElectronic engineeringInverterElectric powerMicrogridbusinessSynchronous motorPulse-width modulationReference frame
researchProduct

Design issues for wind farms grid tied Inverter

2017

In this paper the Authors give indications for the design of a grid tied Voltage Source Inverters (VSI) aimed to optimal use in energy conversion from wind source. In particular, the design of the inverter is more focused on the control system planning, with a particular glance on the grid synchronization problem. After the exposition of general issues concerning renewable energies and associated topics, the case of a grid tied inverter is considered and a methodology of design is sketched starting from the consideration of the DC side and also considering the power device losses, the protection issue against over voltages and over-currents, snubber circuits, heat sinks and, finally the con…

EngineeringSustainability and the Environmentbusiness.industry020209 energy020208 electrical & electronic engineeringElectrical engineering02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciGridwind farms inverter design control systemPower (physics)Renewable energyRenewable Energy Sustainability and the Environment; Automotive Engineering; Electrical and Electronic EngineeringSettore ING-IND/33 - Sistemi Elettrici per L'EnergiaControl systemAutomotive Engineering0202 electrical engineering electronic engineering information engineeringElectronic engineeringSnubberEnergy transformationInverterRenewable EnergyVoltage sourceElectrical and Electronic Engineeringbusiness2017 Twelfth International Conference on Ecological Vehicles and Renewable Energies (EVER)
researchProduct

Design of a grid connected inverter for sustainable small wind farms

2016

The actual definition of sustainability is nowadays widely accepted. It provides a very general indication on what it is, but it reveals unable to assert how it should be reached. However, if one considers the multiplicity of human activities that have led to talk of real process of human settlement on the environment, it is then understood how it is close to the particular mankind activities. Then the task of providing a guidance on what to do within the sustainability concept is delegated case by case. In this paper, with reference to wind renewable source, The Authors give some indications in the design of a voltage source inverters aimed to optimal use of the wind source. In particular …

EngineeringWind powerbusiness.industryProcess (engineering)Renewable Energy Sustainability and the Environment020209 energy020208 electrical & electronic engineeringEnergy Engineering and Power TechnologyControl engineering02 engineering and technologySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciTask (project management)Renewable energyComputer Networks and CommunicationRisk analysis (engineering)Hardware and ArchitectureControl systemSustainability0202 electrical engineering electronic engineering information engineeringInverterVoltage sourcebusiness
researchProduct

A review of multiple faults diagnosis methods in Voltage Source Inverters

2015

This paper examines, as in short review, the methods of diagnosis of simple and multiple faults on Voltage Source Inverter (VSI). The methods examined here are essentially based on the inspection of the load currents. Some of these diagnosis methods are characterized by low computational effort, other for a better reliability avoiding faultless positive tests. Some solutions are characterized by a share of these benefits while others prefer an enforcement of trustworthiness, in spite of the lower calculation amount. The analysis of the technical literature, certainly, offers a glimpse about the creation of new algorithms and significant advances for the future.

Engineeringbusiness.industryFault toleranceSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault (power engineering)A shareFault indicatorReliability engineeringStuck-at faultReliability (semiconductor)Software fault toleranceVoltage sourcebusinessMultiple faultDiagnosiVoltage Source Inverters
researchProduct